BTU Calculator

Estimate how much cooling a room needs. Enter its size and conditions to get the load in BTU per hour, tons and kW, plus the nearest standard air conditioner size.

Free · No sign-up · Runs in your browser

How to use the BTU calculator

Cooling load is the amount of heat that has to be removed from a room every hour to keep it comfortable. In North America it's given in BTU per hour (BTU/h) or tons; most of the rest of the world uses kW. Architects need a sense of it early: it decides whether a wall unit, a ducted split or a central system makes sense, how much space plant needs, and whether a glazing-heavy design is about to create a problem. This calculator gives a quick, defensible figure for a single room or zone.

  1. Enter the room size in feet or metres, including the ceiling height. For open-plan spaces, measure the whole area the unit will serve.
  2. Set sun exposure, climate and insulation. Choose "very sunny" for rooms with large west or south glazing (north glazing in the southern hemisphere), and "heavily shaded" for rooms under deep overhangs or trees.
  3. Add internal gains: the number of people who are regularly in the room, whether it contains a kitchen, and the wattage of any extra equipment such as servers, AV racks or workstations.
  4. Read the results: the load in BTU/h, tons and kW, the load per unit area, and the smallest standard unit size that covers it.

BTU formulas

The base load comes from the ENERGY STAR room air conditioner sizing chart, which sets a capacity for each band of floor area. The calculator then applies the ENERGY STAR adjustments (sun, occupants, kitchen) and three rule-of-thumb factors for climate, ceiling height and insulation.

Base = ENERGY STAR capacity for the floor area
Load = Base × Sun × Climate × max(1, Ceiling ÷ 8 ft) × Insulation
  + 600 × (Occupants − 2) + 4,000 if kitchen + Equipment W × 3.412
Tons = BTU/h ÷ 12,000 · kW = BTU/h × 0.000293

Floor area (ft²)Floor area (m²)Base capacity (BTU/h)
100–1509–145,000
150–25014–236,000
250–35023–337,000–8,000
350–45033–429,000–10,000
450–55042–5112,000
550–70051–6514,000
700–1,00065–9318,000
1,000–1,40093–13021,000–23,000
1,400–2,000130–18624,000–30,000
2,000–2,500186–23234,000

Worked examples

A sunny bedroom

A 14 × 12 ft bedroom is 168 ft², so the base is 6,000 BTU/h. It has a big west-facing window, so add 10% for sun: 6,600 BTU/h. Two people sleep there, so there's no occupant allowance. The nearest standard unit at or above the load is 8,000 BTU/h, though a 6,000 BTU/h unit with good blinds would be close.

Open-plan living and kitchen

A 30 × 20 ft great room is 600 ft², giving a base of 14,000 BTU/h. Four people use it (two over the baseline, so +1,200) and it includes the kitchen (+4,000). The total is 19,200 BTU/h, which is 1.6 tons or about 5.6 kW. An 18,000 BTU/h unit would be slightly small, so specify a 2-ton (24,000 BTU/h) system or split the zone.

A small office in a hot, humid city

A 7 × 5 m office (35 m², 377 ft²) has a 2.7 m ceiling. The base is 9,000 BTU/h. Hot and humid climate: × 1.2 = 10,800. The ceiling is 8.86 ft, so × 1.11 brings it to about 11,960. Three occupants add 600, and 600 W of computers and screens add 2,047. The load is about 14,600 BTU/h (4.3 kW), so a 15,000 BTU/h (4.4 kW) unit fits.

Who this calculator helps

  • Architects setting out plant space, wall unit positions and condenser locations at concept stage.
  • Interior designers checking that a new layout, extra glazing or a kitchen move won't overwhelm the existing cooling.
  • Building services and MEP engineers doing a quick sense check before running a full heat-gain model.
  • Contractors and installers sanity-checking the unit size in a quote.
  • Homeowners and landlords buying a window, portable or mini-split unit for one room.
  • Students learning how area, orientation and internal gains drive cooling demand.

Practical tips

  • Reduce the load before you size the unit. External shading, low-e glass and roof insulation cut heat gain far more cheaply than a bigger compressor. The window-to-wall ratio calculator shows when glazing is driving the load.
  • Check which facades get afternoon sun with the sun path calculator before choosing "very sunny" or "shaded".
  • Get accurate floor areas for irregular rooms from the square footage calculator.
  • Choose the nearest standard size at or just above the estimate. Going two sizes up usually hurts comfort through poor dehumidification.
  • For whole buildings, ducted systems or permit drawings, commission a Manual J or equivalent calculation.

Planning a new layout for the room you're cooling? Upload a photo and try new furniture, finishes and blinds with Room Redesign.

From numbers to pictures

See the space before it's built.

Once the plan works on paper, BasedFrame turns a sketch, a massing model or a site photo into a photoreal render in seconds. Try Sketch to Render or Room Redesign with free credits.

Try BasedFrame free

FAQ

BTU Calculator FAQ

How many BTU do I need per square foot?

A common starting point is about 20 BTU per hour for every square foot of living space. The ENERGY STAR room air conditioner chart is a little more generous for small rooms: 5,000 BTU/h for 100 to 150 ft², 6,000 for 150 to 250 ft² and 12,000 for 450 to 550 ft². Sun, occupants, kitchens and ceiling height then push the figure up or down.

How many BTU do I need for a 12x12 room?

A 12 by 12 ft room is 144 ft², which falls in the 100 to 150 ft² band of the ENERGY STAR chart, so about 5,000 BTU/h. Make it 5,500 BTU/h if the room gets strong afternoon sun, and 4,500 BTU/h if it's heavily shaded.

How do I convert BTU to tons and kW?

One ton of cooling is 12,000 BTU per hour, so divide BTU/h by 12,000 to get tons. One BTU/h is 0.000293 kW, so multiply by 0.000293 (or divide by 3,412) to get kW. A 24,000 BTU/h unit is 2 tons or about 7.0 kW of cooling.

Does ceiling height change the BTU requirement?

Yes. The square-foot charts assume a ceiling of about 8 ft (2.4 m). A taller room holds more air and usually has more wall and glass exposed to heat, so this calculator scales the load in proportion to height above 8 ft. A 10 ft ceiling adds about 25%.

How many BTU does each person add?

ENERGY STAR suggests adding 600 BTU/h for each regular occupant beyond two. A resting adult gives off roughly 400 to 600 BTU/h of sensible and latent heat, and more when active, so meeting rooms and gyms need extra capacity.

Why add 4,000 BTU for a kitchen?

Cooktops, ovens, dishwashers and kettles release a lot of heat while they're running. ENERGY STAR recommends adding 4,000 BTU/h when the unit will cool a kitchen. In an open-plan room, add it once for the kitchen area rather than per appliance.

Is it bad to buy an air conditioner that's too big?

Yes. An oversized unit cools the air quickly and then switches off before it has removed much moisture, so the room feels cold and clammy. It also cycles on and off more, which wastes energy and wears the compressor. Pick the nearest standard size at or slightly above the estimate.

Can I use this instead of a Manual J load calculation?

No. This is a quick estimate for a single room or zone, good for early design, briefs and checking a quote. Whole-house systems, ducted equipment and anything that goes on permit drawings should be sized with ACCA Manual J or an equivalent heat-gain calculation that uses the real wall, roof and glazing construction.