Insulation Calculator

Enter the area, target R-value and any existing insulation to get the thickness you need and how many batts, rolls or bags of blown-in insulation to buy.

Free · No sign-up · Runs in your browser

How to use the insulation calculator

Insulation is specified by thermal resistance, the R-value in the US or RSI in metric countries, but it is bought by the pack or the bag. This calculator connects the two: it turns a target R-value into a thickness, takes off whatever is already there, and tells you how many batts, rolls or bags of loose fill cover your area.

  1. Choose units and type. US mode uses square feet, inches and R-values; metric mode uses square metres, millimetres and RSI with the material's thermal conductivity (λ). Pick batts and rolls, or blown-in loose fill.
  2. Pick the material. This fills in a typical R-value per inch or λ. Overwrite it with the figure on your product label for a closer answer.
  3. Enter the area, the target and any existing insulation. For a top-up, enter the R-value already there. If you only know the depth, multiply it by about R-3 per inch for old fibreglass or rock wool batts (in metric, divide the thickness in metres by its λ).
  4. Enter the product details. For batts and rolls, give the thickness and the coverage per pack. For loose fill, enter the settling allowance and either the bag chart's coverage at your R-value or a density and bag weight for an estimate.

Insulation formulas

Thickness needed = target R ÷ R per inch (metric: thickness = RSI × λ)
Existing R ≈ existing thickness × its R per inch (metric: thickness ÷ λ)
Layers = ⌈(target − existing R) ÷ R of one layer⌉
Packs = ⌈area × layers × (1 + extra %) ÷ coverage per pack⌉
Installed loose-fill depth = settled depth × (1 + settling %)
Bags = area × settled depth × density ÷ bag weight × (1 + extra %), or area ÷ chart coverage

Typical values are about R-3.2 per inch for fibreglass batts, R-4.0 for mineral wool batts, R-3.5 for blown cellulose and R-2.5 for loose-fill fibreglass. One RSI equals R-5.678. Densities for loose fill vary a lot by product, which is why the bag chart is the better source when you have it.

IECC 2021 climate zoneCeilingWood-frame wall
0–1R-30R-13 or R-0 + 10 ci
2R-49R-13 or R-0 + 10 ci
3R-49R-20, R-13 + 5 ci or R-0 + 15 ci
4–8 (and 4C)R-60R-20 + 5 ci, R-13 + 10 ci or R-0 + 15 ci

These are the prescriptive values in IECC 2021 Table R402.1.3, where "ci" means continuous insulation. Jurisdictions adopt different editions and amendments, so confirm the numbers locally. For a full wall or roof build-up, use the R-value and U-value calculator.

Worked examples

Topping up an attic with blown cellulose

A 1,000 ft² attic has 3.5 in of old fibreglass batts, worth about R-11.2 at R-3.2 per inch. Bringing it up to R-49 needs another R-37.8. At R-3.5 per inch, that is 10.8 in of settled cellulose, or about 12.4 in when installed with a 15% settling allowance. At a settled density of 1.5 lb/ft³, the 900 ft³ of cellulose weighs 1,350 lb: 54 bags of 25 lb, or 57 with 5% extra. If the bag chart says one bag covers 16 ft² at R-49, use that instead: 1,000 ÷ 16 = 62.5, or 66 bags with extra.

A metric loft top-up with rolls

A 50 m² loft has 100 mm of glass mineral wool between the joists. With λ = 0.044 W/m·K that is RSI 2.27, which you enter as the existing RSI. To reach the recommended 270 mm (about RSI 6.1), lay one layer of 170 mm roll across the joists, worth RSI 3.86, for a total of RSI 6.14. If one roll covers 6 m², you need 50 × 1.05 ÷ 6 = 8.75, so 9 rolls.

Who this calculator helps

  • Architects and energy assessors turning a specified R-value into a thickness and a quantity for a spec or cost plan.
  • Builders and insulation contractors pricing a retrofit or new-build job quickly.
  • Interior designers and renovators checking how much depth an upgrade will take up in a loft or wall.
  • Homeowners working out how many bags to put in the car for a weekend attic top-up.

Practical tips

  • Air-seal gaps around pipes, wires and light fittings before insulating; insulation doesn't stop air leaks.
  • Keep the eaves ventilated with baffles, and keep insulation the required distance from recessed lights and flues unless they are rated for contact.
  • Fix depth markers or rulers across the attic so you can check the blown-in depth as you go.
  • Work out the area with the square footage calculator, and size heating or cooling with the BTU calculator once the insulation is upgraded.

Planning a loft conversion after the upgrade? Show the client the finished room with Room Redesign.

From numbers to pictures

See the space before it's built.

Once the plan works on paper, BasedFrame turns a sketch, a massing model or a site photo into a photoreal render in seconds. Try Sketch to Render or Room Redesign with free credits.

Try BasedFrame free

FAQ

Insulation Calculator FAQ

How much insulation do I need?

Start with the area you are insulating and the R-value you are aiming for. Divide the target R-value by the material's R-value per inch to get the thickness, then work out how many batts, rolls or bags cover that area at that thickness. For 1,000 ft² of attic at R-38 with fibreglass batts around R-3.2 per inch, you need about 12 in of insulation, for example two layers of 6¼ in batts.

How many bags of blown-in insulation do I need?

Use the coverage chart printed on the bag: it lists the square feet one bag covers at each R-value, plus the installed and settled thickness. Divide your attic area by the coverage at your target R-value and round up. Without the chart, this calculator estimates bags from the settled depth, a typical density and the bag weight, but the manufacturer's chart always wins.

What R-value should my attic be?

Under the 2021 IECC, new homes need ceiling insulation of R-30 in climate zones 0–1, R-49 in zones 2–3 and R-60 in zones 4–8, and ENERGY STAR gives similar ranges for retrofits. In the UK, the Energy Saving Trust recommends 270 mm of mineral wool in a loft. Check the code your jurisdiction has adopted.

How thick is R-38 insulation?

It depends on the material. At about R-3.2 per inch, fibreglass batts need roughly 12 in for R-38. Blown cellulose at about R-3.5 per inch needs around 11 in once settled, and loose-fill fibreglass at about R-2.5 per inch needs roughly 15 in. Product labels give the exact thickness for each R-value.

Can I add new insulation on top of old insulation?

Usually, yes, as long as the old insulation is dry and free of mould or pests, and isn't vermiculite that might contain asbestos. Use unfaced batts or loose fill for the top-up so you don't trap moisture with a second vapour retarder. Laying the new batts across the joists covers the timber and reduces thermal bridging.

Does blown-in insulation settle?

Yes. Loose-fill cellulose in particular settles after it is installed, which is why bag charts list both an initial installed thickness and a minimum settled thickness. The calculator adds a settling allowance to the installed depth, 15% by default for cellulose, so you blow in enough to keep the R-value after it settles.

What is the difference between R-value and RSI?

Both measure thermal resistance. The US R-value is in ft²·°F·h/BTU, while RSI (used in metric countries) is in m²·K/W. To convert, multiply RSI by 5.678 to get the US R-value, so RSI 6.0 is about R-34. In metric mode, the calculator works out RSI from the thickness and the thermal conductivity (λ) on the product label.

How many rolls of loft insulation do I need?

Multiply the loft area by the number of layers and divide by the coverage of one roll, which depends on its thickness and is printed on the pack. A 50 m² loft with 100 mm already in place needs one more layer of 170 mm to reach about 270 mm. If one roll covers 6 m², that is 50 ÷ 6 = 8.3, or 9 rolls with 5% extra.