Electrical Load Calculator

Estimate dwelling service amps from floor area, small-appliance circuits, fixed loads and HVAC using a simplified NEC 220 standard method.

Free · No sign-up · Runs in your browser

How to use the electrical load calculator

Service size drives panel location, feeder conduit and utility coordination. This tool walks through a simplified NEC Article 220 standard-method estimate for a one-family dwelling: general lighting from floor area, small-appliance and laundry circuits, demand factors, fixed appliances, the larger of heat or A/C, optional EV load, and a 25% largest-motor adder. Results are for education and early design — not a permit calculation.

  1. Enter conditioned / dwelling floor area in ft² or m².
  2. Confirm small-appliance and laundry circuit counts (NEC typically requires two SA and one laundry at 1,500 VA each).
  3. Add nameplate or typical VA for range, dryer, water heater and other fixed appliances.
  4. Enter A/C and heating VA — the tool keeps the larger — plus EV and largest motor if known.

NEC 220 standard-method formulas (simplified)

General lighting = 3 VA/ft² × area (or ≈ 33 VA/m² × area)
Small appliance = 1,500 VA × circuits · Laundry = 1,500 VA × circuits
Demand on (lighting + SA + laundry): first 3,000 VA @ 100%, remainder @ 35%
Fixed appliances (4 or more): often × 75% combined (simplified Table 220.53 style)
Range / dryer: use nameplate or typical demand values entered above
HVAC: take the larger of heating VA or cooling VA
Largest motor adder = 25% × largest motor VA
Service amps ≈ total VA ÷ 240 V (single-phase 120/240)
Recommend next standard size: 100 / 150 / 200 / 400 A

Typical presets: electric range 8,000 VA, dryer 5,000 VA, water heater 4,500 VA, 3-ton A/C ~3,600 VA. Replace presets with nameplate values when you have them. Gas appliances that only need ignition should be entered as 0 or a small VA.

Total load (approx.)Common service
≤ 24 kVA100 A
24–36 kVA150 A
36–48 kVA200 A
> 48 kVA320 / 400 A class

Worked examples

A 2,000 ft² three-bedroom house

Lighting = 2,000 × 3 = 6,000 VA. Two SA + one laundry = 4,500 VA. Subtotal 10,500 VA → demand = 3,000 + 0.35 × 7,500 = 5,625 VA. Add range 8,000, dryer 5,000, water heater 4,500, dishwasher/disposal 1,500 — four appliances → 75% × 19,000 = 14,250 VA. A/C 3,600 VA (no electric heat). Total ≈ 5,625 + 14,250 + 3,600 = 23,475 VA → 23,475 ÷ 240 ≈ 98 A → recommend 100 A service if no EV, or step to 150–200 A with margin.

Same house with a 48 A EV charger

A 11.5 kW EVSE continuous is entered as about 11,500 × 1.25 ≈ 14,400 VA for branch sizing; as a connected load adder in this simplified sheet we add 14,400 VA. Total climbs past 37 kVA → about 158 A → a 200 A service is the usual conversation with the electrician.

Metric 180 m² all-electric flat

Lighting ≈ 180 × 33 = 5,940 VA. Same SA/laundry demand path, heat-pump outdoor unit plus strip heat — take the larger (strips often win). Expect a 150–200 A single-phase service depending on cooking fuel and dryer.

Who this calculator helps

  • Architects coordinating panel rooms, meter locations and utility upgrades in schematic design.
  • Design-build and GC teams flagging 100 vs 200 A early so pricing is honest.
  • Homeowners planning EV chargers, heat pumps or all-electric retrofits.
  • Students learning the shape of an NEC 220 standard-method takeoff.

Practical tips

  • Floor area ties to the square footage calculator; lighting design loads sit on the lighting calculator.
  • Fixture counts for wet rooms are on the plumbing fixture calculator; occupancy-driven loads for other building types use the occupancy load calculator.
  • Use nameplate FLA × voltage × √3 (three-phase) or × 1 (single-phase) when you have real equipment data.
  • Continuous loads (EVSE, some heaters) need 125% on the branch-circuit sizing even when demand factors apply at the service.
  • Local amendments and the optional method (220.82) can change the answer — ask the AHJ which path they want on the permit set.

Presenting an all-electric kitchen upgrade? Show the finished space on a photo with Room Redesign.

From numbers to pictures

See the space before it's built.

Once the plan works on paper, BasedFrame turns a sketch, a massing model or a site photo into a photoreal render in seconds. Try Sketch to Render or Room Redesign with free credits.

Try BasedFrame free

FAQ

Electrical Load Calculator FAQ

How do I calculate residential electrical service size?

A common educational approach follows the NEC Article 220 standard method: general lighting at 3 VA per ft² (about 33 VA/m²), two small-appliance circuits at 1,500 VA each, one laundry circuit at 1,500 VA, apply dwelling demand factors, then add fixed appliances, HVAC and a 25% largest-motor adder. Divide total VA by 240 V for single-phase amps and round up to a standard service (100, 150, 200, 400 A).

What demand factors does NEC 220 use for dwellings?

For the general lighting + small-appliance + laundry load in a dwelling, the familiar factors are 100% of the first 3,000 VA and 35% of the remainder (NEC Table 220.42 style for dwellings). Fixed appliances often take 75% when four or more are fastened in place (Table 220.53 style). Ranges, dryers and HVAC have their own notes — this calculator uses simplified typical values.

Do I take air conditioning or heating, or both?

Take the larger of the heating load or the cooling load, not both, when they are not expected to run together. Heat-pump systems need careful reading of the nameplate; emergency heat strips can dominate. The calculator lets you enter both and keeps the larger.

How many VA per square foot for lighting?

NEC general lighting for dwellings is 3 VA per ft² of floor area (including open porches? — usually the conditioned / livable floor area used for the dwelling calculation). In metric that is about 32.3 VA/m²; this tool uses 33 VA/m² as a round figure.

What size service do most houses need?

Many three-bedroom homes land near 100–150 A on a standard-method estimate; larger homes with electric ranges, dryers, tankless water heat, EV chargers or heat pumps often need 200 A. All-electric or EV-ready custom homes may push toward 320/400 A. Always confirm with a full Article 220 calc and the AHJ.

Does an EV charger require a service upgrade?

A 40–60 A continuous EVSE load (32–48 A charge current × 125%) is a large single addition. On a house that already sits near the top of a 100 A panel it often forces a 200 A upgrade or an energy-management system. Enter the EV load in the calculator to see the effect.

What about the optional method (NEC 220.82)?

The optional dwelling method uses a different square-foot rate and demand table and can give a lower service size for qualifying homes. This calculator implements a simplified standard-method path only, which is the conservative teaching example for early design.

Is this calculator a substitute for an electrician?

No. It is an educational estimate for architects and early design conversations. Final service size requires a complete NEC Article 220 calculation (or local amendment), nameplate data, and approval by the authority having jurisdiction. Hire a licensed electrician or electrical engineer for permits.