Egress Window Calculator

Enter the clear opening width, height and sill height of a bedroom or basement window. See whether it meets IRC R310 emergency escape rules and what size the opening needs to be.

Free · No sign-up · Runs in your browser

How to use the egress window calculator

Every bedroom, and every basement with habitable space, needs a way out other than the door. The International Residential Code calls this an emergency escape and rescue opening, set out in section R310, and the window is usually that opening. The rules are short but easy to get wrong, because the size that counts is the clear opening, not the window's nominal or rough opening size. This calculator checks all of the dimensional rules at once.

  1. Pick the window location. Openings above the grade floor need 5.7 ft²; grade-floor and below-grade openings need 5.0 ft².
  2. Enter the clear opening width and height with the sash fully open, from the manufacturer's data or measured on site, and the sill height from the finished floor to the bottom of the clear opening.
  3. Add the window well if the sill is below the ground outside: its projection from the wall, its width along the wall and its depth.
  4. Read the results: clear area, a pass or fail for each rule, the minimum height that would work at your width, and whether the well needs a ladder.

Egress window rules and formulas

Net clear area = clear width × clear height
Area ≥ 5.7 ft² (820.8 in², 0.53 m²), or 5.0 ft² (720 in², 0.46 m²) at grade floor or below grade
Clear height ≥ 24 in (610 mm), clear width ≥ 20 in (508 mm)
Sill height ≤ 44 in (1,118 mm)
Well area ≥ 9 ft², projection and width ≥ 36 in, ladder if depth > 44 in

Meeting the minimum width and minimum height isn't enough on its own: both have to be met and the area too. That is why the tool also tells you the height needed at your chosen width, which is the quickest way to pick a window size from a catalogue.

Window typeShare of the frame that opensNotes for egress
CasementAlmost allEasiest to comply; check the hinge side clearance
Double-hung / single-hungAbout half the heightNeeds a tall unit, often 60 in or more
SliderAbout half the widthNeeds a wide unit to reach 20 in clear
Awning / hopperLimited by the opening angleOften fails; use egress hardware if offered

Worked examples

A second-floor bedroom casement

A casement with a clear opening of 24 × 36 inches and a 40 inch sill. The area is 864 in², or 6.0 ft², above the 5.7 ft² needed. Width, height and sill all pass, so this window works for egress.

A double-hung that looks big enough

A 32 × 54 inch double-hung opens to about 28.5 × 23.5 inches clear. The area is 670 in², or 4.65 ft², and the clear height is under 24 inches, so it fails twice. At a 28.5 inch clear width the opening needs to be at least 28.8 inches tall, so a taller unit or a casement is needed.

A basement bedroom in metric

A below-grade casement of 600 × 900 mm clear has 0.54 m², above the 0.46 m² basement minimum, with a 1,050 mm sill. The well is 950 mm out from the wall, 1,200 mm wide and 1,250 mm deep. Its area is 1.14 m², above the 0.84 m² minimum, but at 1,250 mm deep it is over 1,118 mm, so a fixed ladder is required.

Who this calculator helps

  • Architects and residential designers choosing window sizes for bedrooms and basements at the design stage.
  • Basement and loft conversion contractors checking that a new habitable room can pass inspection.
  • Window suppliers and installers confirming that a replacement window keeps the egress opening.
  • Home inspectors and real estate agents flagging bedrooms that may not count as legal sleeping rooms.
  • Interior designers making sure furniture and built-ins leave the window usable.
  • Homeowners planning a basement bedroom or a replacement window.

Practical tips

  • Ask the manufacturer for the clear opening dimensions; most publish an egress size chart for each unit.
  • Keep the window operable from inside without keys, tools or special knowledge. Security bars need a quick-release.
  • Check the room's floor area for the listing or code with the square footage calculator, and its daylight with the daylight factor calculator.
  • On commercial projects, check exits and egress widths with the occupancy load calculator.
  • Leave the window clear of beds and desks; the furniture clearance guide helps plan the layout.

Planning a basement bedroom? Show the client the finished room before work starts with Room Redesign.

From numbers to pictures

See the space before it's built.

Once the plan works on paper, BasedFrame turns a sketch, a massing model or a site photo into a photoreal render in seconds. Try Sketch to Render or Room Redesign with free credits.

Try BasedFrame free

FAQ

Egress Window Calculator FAQ

What size does an egress window need to be?

Under the International Residential Code (IRC R310), an emergency escape and rescue opening needs a net clear opening of at least 5.7 ft² (0.53 m²), a clear height of at least 24 inches (610 mm) and a clear width of at least 20 inches (508 mm). Openings at grade floor level or below grade can be 5.0 ft² (0.46 m²). The sill must be no more than 44 inches (1,118 mm) above the floor.

Is a 20 by 24 inch window big enough for egress?

No. Those are the minimum width and height, but 20 × 24 inches is only 480 in², or 3.33 ft², well short of 5.7 ft². To reach 5.7 ft² (820.8 in²) a 20 inch wide opening needs to be about 41 inches tall, and a 24 inch tall opening needs to be about 34.2 inches wide.

What is net clear opening?

It is the actual open area a person can climb through when the window is opened normally, measured between the sash, frame and any stops, without removing parts. It is always smaller than the window's rough opening or frame size, so measure the open sash, or use the manufacturer's published clear opening figure.

Which rooms need an egress window?

The IRC requires an emergency escape and rescue opening in every sleeping room and in basements and habitable attics, with some exceptions such as basements used only for mechanical equipment under a size limit. Each bedroom in a basement needs its own opening. Local amendments can change these rules, so check with your building department.

Do double-hung windows work for egress?

They can, but only the open half counts, so a double-hung or single-hung window must be much taller than a casement to reach 5.7 ft². Casement windows usually make the easiest egress windows because nearly the whole sash swings clear. Sliders also halve the clear width.

What are the window well requirements?

When the sill is below the adjacent ground, the IRC requires a window well with a horizontal area of at least 9 ft² (0.84 m²) and a minimum horizontal projection and width of 36 inches (914 mm). The well must let the window open fully. If the well is deeper than 44 inches (1,118 mm), it needs a permanently fixed ladder or steps.

Can the sill be higher than 44 inches if I add a step?

The 44 inch limit is measured from the finished floor to the bottom of the clear opening. Recent IRC editions allow a permanently fixed step or platform under the window to reduce the effective sill height, within limits on its size and height. Movable furniture doesn't count. Check your adopted code edition before relying on a step.

Does this calculator replace an inspection?

No. It checks the dimensional rules of IRC R310 with the numbers you enter, which is useful for design and window selection. Your local building department decides which code edition and amendments apply, and the inspector has the final word on the installed window.

Keep exploring

More free tools for architects

Turn any listing
into rooms that sell