R-Value and U-Value Calculator

Build up a wall, roof or floor layer by layer. Get the total R-value, U-factor and metric RSI, the effect of studs or rafters, and a check against IECC 2021 targets.

Free · No sign-up · Runs in your browser

How to use the R-value calculator

The R-value printed on a batt of insulation is not the R-value of the wall. Drywall, sheathing, cladding and the thin layers of still air on each face all add resistance, while studs and rafters let heat bypass the insulation. This calculator adds those parts up the way energy codes and building scientists do, so you can compare build-ups and see how close a design is to the code target.

  1. Pick the assembly, a wall or a roof or ceiling. That sets the inside air film and the code target.
  2. Add the layers from inside to outside. Choose a material, enter its thickness, and tick "in cavity" for insulation that sits between studs or rafters.
  3. Set the framing share. About 25% suits 2x4 or 2x6 walls at 16 inches on centre, 22% at 24 inches, and 10–15% for roof rafters or joists.
  4. Choose your IECC climate zone to compare the result with the residential U-factor limit.

R-value and U-value formulas

Layer R = thickness × R per inch (or a fixed R)
Cavity path R = air films + all layers
Framing path R = air films + other layers + cavity depth × R-1.25 per inch (wood)
Effective U = framing % ÷ R framing + (1 − framing %) ÷ R cavity
Effective R = 1 ÷ U · RSI = R × 0.1761 · U (W/m²K) = 1 ÷ RSI

This is the parallel path method from ASHRAE Fundamentals. It works well for wood framing. Steel studs conduct far more heat, so a steel-framed wall loses much more than this calculation shows and should be checked with the code's correction factors.

MaterialR per inchRSI per 25 mm
Fibreglass batt3.20.56
Mineral wool batt4.00.70
Blown cellulose3.50.62
Open-cell spray foam3.70.65
Closed-cell spray foam6.51.14
EPS / XPS / polyiso board4.0 / 5.0 / 6.00.70 / 0.88 / 1.06
Softwood, plywood, OSB1.250.22
Gypsum board0.90.16
Brick / concrete0.2 / 0.080.035 / 0.014

Worked examples

A basic 2x4 wall

Inside air film 0.68, 1/2 inch drywall 0.45, 3.5 inches of fibreglass batt 11.2, 7/16 inch OSB 0.55, vinyl siding 0.61 and outside air film 0.17 add up to R-13.7 through the cavity. Through the studs, the 3.5 inches of wood give only R-4.4, so that path is R-6.8. With 25% framing the effective U is 0.25 ÷ 6.8 + 0.75 ÷ 13.7 = 0.091, or about R-11. The batt's label says R-11 to R-13, yet the whole wall barely matches it.

Adding an inch of polyiso outside

The same wall with 1 inch of polyiso over the OSB adds R-6 to both paths. The cavity path is R-19.7 and the stud path R-12.8, so the effective U drops to 0.058, about R-17.3. One inch of board added more than R-6 to the whole wall because it covers the studs too, while the batts lose a good part of their rating to the framing.

An attic in metric

A ceiling of 12.5 mm plasterboard with 300 mm of blown cellulose between and over 140 mm joists, entered as 140 mm in cavity and 160 mm continuous, comes to around RSI 7.1, or R-40.6, with 12% framing. That gives a U-value of about 0.14 W/m²K, or U-0.025 in imperial units. It meets the zone 3 limit of U-0.026 but falls just short of U-0.024 in zones 4 to 8, so about 25 mm more cellulose would get it there.

Who this calculator helps

  • Architects and building designers comparing wall and roof build-ups before choosing a specification.
  • Energy consultants and HERS raters making a quick check before a full model.
  • Builders and insulation contractors explaining to clients why continuous insulation matters.
  • Students learning how R-values, U-values and thermal bridging relate.
  • Renovators and homeowners deciding how much insulation to add to an attic or wall.

Practical tips

  • Use the R-value from the product data sheet when you know the product; generic values are averages.
  • Glazing usually dominates heat loss; check how much of the facade is glass with the window-to-wall ratio calculator.
  • Better insulation shrinks the cooling load; see the effect with the BTU calculator.
  • Thicker walls change stud and rafter sizes; check spans with the joist and rafter span calculator.
  • Keep the vapour control layer on the warm side in cold climates, and check the dew point for interior insulation.

Presenting an energy retrofit? Show the finished facade to the client with Exterior Redesign.

From numbers to pictures

See the space before it's built.

Once the plan works on paper, BasedFrame turns a sketch, a massing model or a site photo into a photoreal render in seconds. Try Sketch to Render or Room Redesign with free credits.

Try BasedFrame free

FAQ

R-Value and U-Value Calculator FAQ

How do you calculate the R-value of a wall?

Add up the R-value of every layer, from the inside air film to the outside air film. Each layer's R-value is its thickness times its R-value per inch, or a fixed figure for products like siding and air gaps. A wall of 1/2 inch drywall, R-13 batts, 1/2 inch OSB and vinyl siding comes to about R-15.5 through the insulated cavity before the studs are taken into account.

What is the difference between R-value and U-value?

R-value measures resistance to heat flow, so higher is better. U-value, also called U-factor, measures how much heat flows through, so lower is better. They are reciprocals for a whole assembly: U = 1 ÷ total R. A wall of R-20 total has a U-factor of 0.050 Btu/h·ft²·°F.

How do I convert R-value to RSI and U-value in W/m²K?

Multiply an imperial R-value by 0.1761 to get RSI in m²·K/W. R-20 is RSI 3.52. The metric U-value is 1 ÷ RSI, so R-20 is about 0.28 W/m²K. To go from metric back to imperial, divide RSI by 0.1761.

Why does framing reduce the R-value?

Wood studs conduct heat about three times faster than insulation, so heat bypasses the batts through the framing. In a typical 2x4 wall at 16 inches on centre, framing covers around 25 percent of the area. The calculator uses the parallel path method, adding the U-values of the cavity and stud paths by their area share, to give an effective whole-wall figure.

What R-value do I need for walls and attics?

Under IECC 2021 for homes, attic ceilings need R-30 in climate zone 1, R-49 in zones 2 and 3, and R-60 in zones 4 to 8. Wood frame walls need R-13 in zones 0 to 2, R-20 or R-13 plus R-5 continuous insulation in zone 3, and roughly R-20 plus R-5 continuous insulation in colder zones. Local codes can be stricter.

What is continuous insulation?

Continuous insulation, written ci, is a layer of rigid board or spray foam that runs across the framing without interruption, usually outside the sheathing. Because no studs break it, it keeps its full R-value and cuts thermal bridging. That is why codes treat R-13 + R-5ci as better than R-20 in the cavity alone.

What are air film R-values?

Still air next to a surface adds a little resistance. Standard design values are about R-0.68 for an inside wall surface, R-0.61 for an inside ceiling with heat flowing up, and R-0.17 for an outside surface in wind. The calculator adds these automatically so the total matches how assemblies are rated.