Ventilation Rate Calculator

Enter the floor area, ceiling height and bedrooms to get the ASHRAE 62.2 whole-house ventilation rate, the IRC rate, air changes per hour and local exhaust.

Free · No sign-up · Runs in your browser

How to use the ventilation calculator

Airtight, well-insulated homes need mechanical ventilation to remove moisture, CO₂ and indoor pollutants. ASHRAE Standard 62.2 is the reference for how much outdoor air a dwelling needs, and building codes base their rules on it. This calculator gives the whole-house rate from the floor area and number of bedrooms, converts it to air changes per hour and lists the kitchen and bathroom exhaust you need on top.

  1. Choose units. US mode works in square feet and cfm; metric mode works in square metres and litres per second, with m³/h shown too.
  2. Enter the conditioned floor area of the dwelling, the average ceiling height and the number of bedrooms.
  3. Set the fan run time if the system runs on a timer rather than continuously.
  4. Enter the kitchens and bathrooms to total the local exhaust requirement.

Ventilation formulas

ASHRAE 62.2-2016+: Q = 0.03 × A + 7.5 × (Nbr + 1) cfm · Q = 0.15 × A + 3.5 × (Nbr + 1) L/s
IRC / ASHRAE 62.2-2010: Q = 0.01 × A + 7.5 × (Nbr + 1) cfm · Q = 0.05 × A + 3.5 × (Nbr + 1) L/s
Intermittent fan rate ≈ Q ÷ run-time fraction
ACH = cfm × 60 ÷ ft³ · ACH = L/s × 3.6 ÷ m³

A is the conditioned floor area and Nbr is the number of bedrooms. The current ASHRAE rate is the total requirement before any infiltration credit; with a blower door result, some editions let you reduce the fan size. The intermittent figure is a simplified check, since the standard has extra limits on how long a fan may stay off.

Local exhaustOn demandContinuous
Kitchen100 cfm (50 L/s)5 ACH of kitchen volume
Bathroom50 cfm (25 L/s)20 cfm (10 L/s)

Worked examples

A three-bedroom house

A 2,000 ft² house with three bedrooms and 8 ft ceilings needs 0.03 × 2,000 + 7.5 × 4 = 60 + 30 = 90 cfm under ASHRAE 62.2. The IRC formula gives 20 + 30 = 50 cfm. The house volume is 16,000 ft³, so 90 cfm is 90 × 60 ÷ 16,000 = 0.34 air changes per hour. If the fan runs only half of each hour, it needs to move about 180 cfm while it is on. One kitchen and two bathrooms add 100 + 2 × 50 = 200 cfm of on-demand exhaust.

A two-bedroom flat in metric

A 150 m² dwelling with two bedrooms and 2.5 m ceilings needs 0.15 × 150 + 3.5 × 3 = 22.5 + 10.5 = 33 L/s, or 118.8 m³/h. The volume is 375 m³, so the rate is 33 × 3.6 ÷ 375 = 0.32 ACH. That is a good size for a heat recovery ventilation unit running on its normal setting, with a boost mode for cooking and showers.

Who this calculator helps

  • Architects sizing the ventilation strategy and plant space for new homes and deep retrofits.
  • Energy raters and HERS raters checking a design against ASHRAE 62.2 quickly.
  • HVAC designers and installers choosing an HRV, ERV, supply or exhaust fan.
  • Self-builders and renovators who have made a house airtight and need to plan fresh air.

Practical tips

  • Ventilation air is also a heat load. Use the heat loss calculator to see how much it adds, and why heat recovery pays back in cold climates.
  • Check the cooling side with the BTU calculator and the envelope with the R-value calculator.
  • Fans rarely deliver their rated flow once ducts are attached. Measure the installed flow and choose a fan with some margin.
  • Supply fresh air to bedrooms and living rooms and extract from kitchens and bathrooms so air moves through the home.

Presenting a retrofit to a client? Show them the finished interior on a photo of their own home with Room Redesign.

From numbers to pictures

See the space before it's built.

Once the plan works on paper, BasedFrame turns a sketch, a massing model or a site photo into a photoreal render in seconds. Try Sketch to Render or Room Redesign with free credits.

Try BasedFrame free

FAQ

Ventilation Rate Calculator FAQ

How do I calculate whole-house ventilation?

ASHRAE 62.2-2016 and later set the total whole-house rate as Q = 0.03 × floor area (ft²) + 7.5 × (bedrooms + 1) in cfm. In SI units it is Q = 0.15 × floor area (m²) + 3.5 × (bedrooms + 1) in L/s. A 2,000 ft² house with three bedrooms needs 60 + 30 = 90 cfm of continuous outdoor air.

Why does the IRC give a lower number than ASHRAE 62.2?

The IRC and the older ASHRAE 62.2-2010 use 0.01 cfm per square foot instead of 0.03, so the same 2,000 ft², three-bedroom house needs 20 + 30 = 50 cfm. The 2016 edition raised the area term but lets you subtract an infiltration credit measured with a blower door test, which this calculator does not apply.

How many air changes per hour does a house need?

There is no single ACH requirement in ASHRAE 62.2; it sets a flow in cfm instead. Converted, most homes land between about 0.25 and 0.4 air changes per hour of mechanical ventilation. The older 0.35 ACH guideline from ASHRAE 62-1989 is still often quoted as a rule of thumb.

How do I convert cfm to air changes per hour?

ACH = cfm × 60 ÷ volume in cubic feet. In metric, ACH = L/s × 3.6 ÷ volume in cubic metres. For example, 90 cfm in a 16,000 ft³ house is 90 × 60 ÷ 16,000 = 0.34 ACH.

What if my ventilation fan doesn't run all the time?

An intermittent system has to move more air while it runs. As a simple check, divide the continuous rate by the fraction of time the fan is on: a 90 cfm requirement at 50% run time needs about 180 cfm. ASHRAE 62.2 adds further rules for long off periods, so use a scheduled controller and check the standard for the final design.

How much exhaust does a kitchen or bathroom need?

ASHRAE 62.2 asks for local exhaust of at least 100 cfm (50 L/s) on demand in a kitchen, or 5 air changes per hour continuous, and 50 cfm (25 L/s) on demand or 20 cfm (10 L/s) continuous in each bathroom. Local exhaust is in addition to the whole-house rate.

Does the number of bedrooms really matter?

Yes. Bedrooms + 1 is used as a proxy for the number of occupants, because people are the main source of moisture and CO₂ in a home. A one-bedroom flat is assumed to have two occupants and a four-bedroom house five.

Is this calculator enough for a permit?

It gives the standard formulas and a quick check, which is enough for early design and sizing an HRV, ERV or exhaust fan. Your local code may adopt a different edition, require a specific table or allow infiltration credits, so confirm the required rate with the code that applies to your project.