Water Heater Size Calculator

Size a tank by first-hour rating or a tankless unit by peak flow from fixtures, people and temperature rise.

Free · No sign-up · Runs in your browser

How to use the water heater size calculator

Hot-water shortages show up at peak hour — usually morning showers overlapping with laundry or a dishwasher. This tool estimates the first-hour rating a storage tank needs, or the peak flow a tankless heater must support, from household size, simultaneous fixtures and temperature rise. Figures are labelled estimates for early design, not a stamped equipment schedule.

  1. Choose units and heater type — tank (FHR) or tankless (peak gpm / L/min).
  2. Pick household size from the bedroom / people bands that DOE-style guides use.
  3. Enter inlet and desired temperatures so the tool can compute temperature rise and tankless BTU or kW.
  4. Count fixtures that can run together at the peak hour, then read the recommended tank size and minimum FHR, or the peak flow and fuel input for tankless.

Water heater sizing formulas

Temperature rise ΔT = Thot − Tcold
People-based FHR (approx.): 1–2 people → 45–55 gal; 2–3 → 55–65; 3–4 → 65–75; 4–5 → 75–85; 5–6 → 85–100+ gal
Fixture peak draw ≈ showers×gpm + sinks×gpm + dishwasher + washer volume/hour + baths×volume
Tank FHR needed ≈ max(people table, fixture peak draw in that hour)
Suggested tank gallons ≈ FHR × 0.7 to 0.85 (typical usable fraction of rated FHR)
Tankless peak gpm = sum of simultaneous fixture flows
Gas input ≈ gpm × 500 × ΔT BTU/h · Electric ≈ L/min × ΔT × 0.07 kW (approx.)

Default fixture flows used here: shower 2.0 gpm (7.6 L/min), lav/sink 1.5 gpm (5.7 L/min), dishwasher ~1.5 gpm equivalent during a short draw, clothes washer ~2.0 gpm equivalent, bathtub ~15–20 gallons (55–75 L) of hot water per fill credited to the peak hour. Recovery on a tank is approximated so a stated tank size can be checked against the needed FHR.

HouseholdTypical tankMin FHR (approx.)
1–2 people30–40 gal45–55 gal
2–3 people40–50 gal55–65 gal
3–4 people50–60 gal65–75 gal
4–5 people60–75 gal75–85 gal
5–6+ people75–80+ gal85–100+ gal

Worked examples

A three-bedroom house with one shower peak

Three to four people, inlet 50°F, setpoint 120°F (ΔT = 70°F). One shower, one lav and a dishwasher overlapping need about 2.0 + 1.5 + 1.5 ≈ 5 gpm of hot water if they all run hard, but for a tank the people table already points to roughly 65–75 gal FHR and a 50–60 gal tank. A 50 gal Energy Star unit with a solid recovery rate often lands near 65–70 gal FHR — enough for this peak if baths are staggered.

Tankless for two showers in a cold climate

Two showers at 2.0 gpm plus one lav at 1.5 gpm is 5.5 gpm peak. With 40°F inlet water and 120°F outlet, ΔT = 80°F. Required gas input ≈ 5.5 × 500 × 80 = 220,000 BTU/h. Many residential tankless units top out near 180,000–199,000 BTU/h, so you either reduce simultaneous fixtures, raise inlet temperature with a tempering strategy, or step up to a larger / commercial unit — the calculator flags that limit.

Metric flat with a compact tank

A two-person flat with 10°C inlet and 49°C setpoint (ΔT = 39°C), one shower and one sink. The people band suggests about 170–210 L of FHR and a 120–150 L tank. Peak flow is roughly 7.6 + 5.7 ≈ 13 L/min, which a mid-size tankless can also cover if electrical or gas supply allows.

Who this calculator helps

  • Architects and housing designers picking plant space and fuel type early in schematic design.
  • Plumbers and mechanical contractors cross-checking FHR or tankless gpm before ordering.
  • Homeowners and renovators replacing an undersized heater after morning shortages.
  • Energy raters comparing tank standby loss versus tankless peak capacity in retrofit packages.

Practical tips

  • Count fixtures that can truly run together; a locked bathroom door often means one shower, not three.
  • Set the tank thermostat to about 120°F (49°C) for scald and standby control unless a higher setting feeds a mixing valve.
  • Check plant ventilation and combustion air with the ventilation calculator, and envelope loads with the heat loss calculator.
  • Fixture counts for code minimums live on the plumbing fixture calculator — that is a different problem from peak hot-water flow.
  • Gas tankless units need adequate meter and pipe capacity; electric tankless units often need a large dedicated service.

Showing a client a renovated bath layout around the new heater? Mock it up on a photo with Room Redesign.

From numbers to pictures

See the space before it's built.

Once the plan works on paper, BasedFrame turns a sketch, a massing model or a site photo into a photoreal render in seconds. Try Sketch to Render or Room Redesign with free credits.

Try BasedFrame free

FAQ

Water Heater Size Calculator FAQ

How do I size a tank water heater?

Match the first-hour rating (FHR) to peak morning or evening demand. A rule of thumb is about 10 gallons of FHR per person for a typical household, then add for baths and appliances. Manufacturers publish FHR on the EnergyGuide label; a 40–50 gallon tank often delivers about 50–70 gallons in the first hour depending on recovery rate and temperature rise.

What is first-hour rating (FHR)?

FHR is how many gallons of hot water a tank can deliver in one hour starting full. It combines stored volume with recovery: roughly usable tank capacity plus the gallons the burner or elements can heat in that hour. DOE and Energy Star use FHR (not just tank gallons) to compare models.

How do I size a tankless water heater?

Add the flow rates of fixtures that will run at the same time (showers, lavs, kitchen, dishwasher, washer), then size for that peak gpm at your temperature rise. Required input ≈ gpm × 500 × ΔT in BTU/h for gas, or the SI equivalent in kW. Cold climates need more BTU or kW for the same shower count.

What temperature rise should I use?

Temperature rise = desired outlet temperature − incoming cold-water temperature. Many homes aim for 120°F (49°C) at the tank. Ground water can be 40–50°F in winter in cold climates and 60–70°F in warm climates, so ΔT often ranges from about 50 to 80°F (28–45°C).

How many gallons per minute does a shower use?

Modern WaterSense showers are about 1.5–2.0 gpm; older heads can be 2.5 gpm or more. A bathtub fill is better treated as a volume (about 20–40 gallons) than a continuous gpm for tank FHR. Kitchen and lavatory faucets are often 1.0–1.5 gpm; dishwashers and clothes washers use about 4–8 gallons per cycle rather than continuous flow.

Tank or tankless — which is better?

Tank units are simpler and handle short peak draws from stored heat. Tankless units save standby loss and can run endlessly if the flow stays within the unit's gpm rating, but they need larger gas lines or high electrical service and struggle with very cold inlet water at high simultaneous flows.

Does household size matter more than fixture count?

Both matter. People-based tables (DOE-style) give a quick tank FHR target from bedrooms or occupants. Fixture-based peaks matter more for tankless sizing and for homes with many baths that can run together. Use both checks and take the more conservative result for early design.

Is this calculator enough to specify equipment?

It is an educational estimate for early design and shopping. Final selection needs manufacturer performance tables at your actual temperature rise, gas supply or electrical service limits, venting, and local code. Have a plumber or mechanical designer confirm the model.